Marvel 60CIM-SS-F Guía para resolver problemas Pagina 5

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 28
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 4
INSTALLING THE DRAIN PLUMBING
Drain Plumbing
Your ice machine uses a gravity drain (Figure 3) that re-
quires 5/8” I.D. tubing from the back of the ice machine
to a plumbed connection to a sanitary sewer. Remove the
access panel to plumb in drain connection. Gravity drain
location for built-in units can be within the area shown
in Figure 5. An optional drain pump (Figure 4) can be
purchased for your ice machine if a gravity drain is not ac-
cessible. See page 5 for optional drain pump installation.
Observe and follow all local codes when installing ice
machine.
Failure to use adequate drainage system will result in
surrounding water damage and/or poor ice production.
4
Figure 5
Drain
Access
Figure 4
Figure 3
Access
panel
Access
panel
1-1/2” Drain pipe
Vista de pagina 4
1 2 3 4 5 6 7 8 9 10 ... 27 28

Comentarios a estos manuales

Sin comentarios