APPENDIX A, ADDITIONAL MicroSentry™ FEATURES
Informaon Menu:
The following features are available on the Informaon Menu.
Current Temperature
Maximum Stored Temperature
Minimum Stored Temperature
Total Operang Time Of The Condenser
Keypad Lockout
To access the Informaon Menu Press “SET” buon momentarily
and release.
Once in the informaon menu, the WARMER and COLDER keys
may be used to scroll through the informaon menu. Addion-
ally, pressing and releasing the SET key will advance the informa-
on menu.
The informaon menu will automacally exit aer several sec-
onds with no key presses.
Current Interior Temperature (tI): Press and
hold the “SET” key to display the current inte-
rior temperature.
Maximum Stored Temperature (thi): Maxi-
mum stored temperature is the maximum
temperature refrigerator has achieved since tem-
perature set point was entered. Press and hold the “SET” key
to display the maximum temperature stored. The data can be
cleared by pressing “SET” and “ON/OFF” simultaneously while
the value is displayed. NOTE: It is normal for refrigerator tem-
perature to uctuate from set point by several degrees.
Minimum Stored Temperature (tLO): Mini-
mum stored temperature is the minimum
temperature refrigerator has achieved since tem-
perature set point was entered. Press and hold the “SET” key
to display the minimum temperature stored. The data can be
cleared by pressing “SET” and “ON/OFF” simultaneously while
the value is displayed. NOTE: It is normal for refrigerator tem-
perature to uctuate from set point by several degrees.
Total Operang Time of the Condenser Since
the Last Cleaning (cnd): Press and hold the
“SET” key to display the total operang hours of
the compressor since the last cleaning. The control stores the to-
tal operang hours of the compressor to determine the volume
of air that has moved across the condenser coils. This number
is displayed in weeks. A reminder is displayed when a cleaning is
recommended (see Alarm Codes). The recommended cleaning
period is the equivalent of one year of air volume. The data can
be cleared by pressing the “SET” and “ON/OFF” keys simultane-
ously while the value is displayed.
Keypad Lockout Feature (Loc): This feature
is useful for prohibing changes in the
temperature set point or accidentally turning the
unit o. Press and hold the “SET” key to display the cur-
rent “Loc” seng. If “No” is displayed, Lock
out is OFF and all keys are enabled. If “Yes”
is displayed, Lockout is ON and the “ON/OFF”, “WARMER”, and
“COLDER” keys are disabled. However, the key tones remain
enabled. While holding the “SET” key, press the “WARMER” or
“COLDER” key to select the desired state. Release the “SET” key
to conrm the selecon.
NOTE: The Informaon/Lockout Key “SET” remains enabled
regardless of the “Loc” seng.