DRAIN PUMP REMOVAL INSTRUCTIONS
Additional issues to be inspected by the in-
staller upon service replacement:
1. The drain pump must be level.
2. No pinched water lines.
3. No interference with electrical cords or wiring.
4. The drain pump should not set on any obstacles, wir-
ing, etc.
5. Secure all hose clamps leading to and from the drain
pump.
6. Insure that the vent tube height is adequate - 18 inches
minimum.
7. Insure that drain height is adequate - maximum of 8
feet.
8. Insure that drain length is adequate - maximum of 20
feet.
9. Checked for water leaks after installation of the drain
pump.
10. Check for vibrations caused by improper installation.
11. Insure that there is no interference with back access
cover.
12. Insure that the hole grommets are in place at each
location so that any vent or drain tubes do not rub on
any sharp surfaces.
Ice machine
power cord
Figure 47
Rotate drain pump and
remove from back of
ice machine.
Figure 46
6. Rotate the drain pump and remove from the ice ma-
chine, (See Figure 46). It may be necessary to discon-
nect the ground wire connection in the back ange of
the cabinet. (See Figure 42).
7. Disconnect the ice machine power cord from the drain
pump (See Figure 47).
8. Drain the water in the drain pump’s reservoir by turn-
ing the pump upside down and allowing water to drain
through the pump’s inlet and vent tube ttings.
9. Installation of drain pump is reverse of this procedure.