- 3 -
1.2 Serial Nameplate
The serial nameplate is located on the bottom flange directly above the grille on all
Marvel units. Figure 1.1 gives the information that is provided.
The serial number will need to be given whenever parts are ordered or when inquiring
about the ice maker.
1.3 Before Servicing
h Power to the ice maker must be off before any attempt to service. This can be done by
unplugging the unit or disrupting power to the ice maker receptacle. Verify power is
disconnected to unit.
h If unit has been running, use caution around condenser and copper tubing. These
areas may be very hot.
h Use caution around condenser fins and baseplate edges. These areas can be sharp.
h Refrigerant is under high pressure. Evacuate system before attempting to open
refrigerant system.
h Reasonable care and safe work methods should be practiced when working on the ice
maker. Do not work with energized electrical equipment in wet or damp areas.
h Use an appropriate work area and location when performing repairs. You will find
that it is easier to perform work on the ice maker if set on a raised platform or work
table.
h Wear protective safety glasses when performing any kind of work.
h Any refrigerant, whether CFC, HCFC, or HFC (R-12, R-22, or R-134A) must be
recovered. Federal regulations prohibit the intentional venting or release of
refrigerants during the service repair or disposal of an appliance.
Figure 1.1