Problem Possible Cause Remedy
Unit too warm or too cold inside. Control set too warm or cold•
Temperature control slide in the •
refrigerator section too far open or
closed.
Airflow to front grille blocked.•
Excessive usage or prolonged door •
openings.
Door gasket not sealing properly.•
Adjust temperature colder or •
warmer as required. Allow 24
hours for temperature to stabilize.
Adjust temperature control slide as •
necessary in the refrigerator sec-
tion of the unit.
Airflow must not be obstructed to •
front grille. See “clearances” on
page 3.
Allow temperature to stabilize for •
at least 24 hours.
Adjust or replace door gasket.•
No interior light in compartments. Light bulb burned out.• Replace light bulb.•
Light will not go out when door is
closed
Door not activating light switch.• Verify cabinet is level, refer to page •
3 for leveling instructions.
Verify the door is aligned properly, •
refer to page 8 for instructions.
Noise or Vibration Unit not level•
Water line tubing vibration.•
Level unit, see “Leveling Legs” on •
page 3.
Adjust the tubing as necessary to •
eliminate unwanted vibrations.
Unit will not run. Unit turned off•
Power cord not plugged in.•
No power at outlet.•
Turn unit on. See “Set the tempera-•
ture control” on page 4.
Plug in power cord.•
Check house circuit.•
Moisture collects on outside surface of
cabinet.
Hot and humid conditions.• Extremely hot and humid condi-•
tions can cause condensation on
outside of the cabinet. As humidity
and/or temperature decreases, the
condensation will disappear.
Moisture collects on inside of the unit. To many door openings.•
Prolonged door openings.•
Hot and humid conditions•
Defrost thermistor out of specifica-•
tion.
Limit the amount of door open-•
ings.
Limit the amount of time with the •
door open.
Extreme hot and humid conditions. •
Move unit to a controlled environ-
ment. May consider having the
defrost setting changed from 12
hours to 6 hours.
Consult dealer or servicer for •
diagnosis.
The unit is warm inside with the tem-
perature control knob in the “OFF
position.
Drip tray heater is on.• The drip tray heater will stay ener-•
gized in the off position. Unplug
the unit if storing or leaving the
unit off for an extended period.
Items on door shelf sometimes freeze. The upper 2 shelves can freeze •
under warm conditions.
Turn the temperature control knob •
to a lower number or move the
commodities to the refrigerated
section.